Vectron - Program Printer

Vectron - Program Printer

If Print Data is set under Net/Comm parameters then the till selected will handle all of the printing information.
Print Data allows a till to send all of its print jobs to the till set in the parameter. e.g Print Data = 3, the till will send its jobs to ECR 3. Print Data uses the programming settings of the till selected, not the till the job was created in. Therefore if Print Data is set to 3 on till 1, changing the printer programming on till 1 will not effect printing on till 1 or till 3. This includes drivers, output formats and the rest.

If you need multiple copies of the same receipt, common instance is Kitchen Dockets. The drivers have to be different for the printing to work correctly. This is why there are most likely 2/3 Kitchen Printers.
The departments required should be set to send the first job to e.g Printer 3, the second to Printer 4. Printer 4 would be a copy of Printer 3, so it points to the same hardware with the only change being the Printer Driver. The Printer Driver used is likely a copy of the original driver as the data doesn't have to be different, it just needs to be a different reference.

Number

Reference Number

Name

Name of Printer Reference

ECR

Choose which till the printer is connected to

Port

Choose which port the printer is connected to. Make sure the port has the right settings also, baudrate, handshaking etc.

Pre prog. driver

Set to yes of you are using a pre-installed printer driver. Used with VPOS PC to set the driver to file which allows receipts to print to a .txt file

Printer drivers

Select which printer driver to use. Receipt copies need to use different drivers. Can be the same data but different driver reference is required to work properly

Backup printer

Select which printer should be used instead in case of a printer error

Format profile

Select which format profile to use. Default is 1

Logo number

Set which logo is printed if one is configured to do so.

Error mode

0 - auto redirects if an error is given
1/2 - asks to redirect, defaults to yes/no respectively
3 - outputs error messages but ignored the redirect

Port timeout

unused

Net timeout

unused

Queue timeout

unused

Timeout for reading

unused

Timeout till avail.

unused

Offline

unused

    • Related Articles

    • Vectron - Important Program Links

      ECR Config Program ProgramLinks Parameters Use the following: 1-80 115 142
    • Vectron - Program Departments

      Number Reference for linking to PLUs and other areas Name Only seen through reporting tools. Keep descriptive Icon Unused Main group 1 Main Group report is handy for reporting specific departments. E.g Open food, tobacco, deposits. Set the number to ...
    • Adding products to Vectron

      1. Open Vectron Commander, press ECR programs > Edit and select desired till. 2. Press Transmit ECR programs. 3. select the relevant till and press Continue. 4. Select what data has changes and press Continue. 5. Select if you want to send all data ...
    • Vectron - Program Operator Groups

      Number Reference number Name Name of Operator group Needs sign in unused Mode Manager overwrite - Allows the operator to sign on over the operator currently signed on. Only works with forced tables Training - Enable training mode, anything done in ...
    • Vectron - Program PLU Selections

      If you are configuring a PLU selection I would recommend using the Assistant (ECR Programs/Assistants/PLU selection) as it is a far easier way to view and edit the selections Edit (right) Used to add PLUs to the PLU selection. Can also add PLU ...